- Measured
- At 0.258 %/day
Plant FP-924 · 2,952 kWp · 4,840 modules
Cleaning savings audit
Routine cleaning saves about ₹0.91 L a year, not ₹3.65 L. The earlier figure is the top of a ₹0 to ₹5.54 L range.
Verdict. Scenario B is the headline.
Realistic net savings₹0.91 La yearScenario B
Cleaning interval31dry days4 rounds a year
Range, A to C₹0–5.54 La yearSet by the dust rate
Earlier figure₹3.65 La yearUpper bound only
Downtime costs more than dust
Inverter trips, derates and days with no output lost 81,735 kWh in 295 days. Cleaning cannot recover it; fixing faults faster can.
Lost to downtime, 295 days81,735kWh₹6.33 L at ₹7.75/kWh
Lost a year, pro rata₹7.84 La year8× what cleaning saves in B
Share of the plant's energy2.16%130 events, 1 Feb to 22 Nov 2026
Worst blockCarport38,193 kWh lost
Why ₹3.65 L is the upper bound
It rests on a 0.258 %/day dust rate from step detection. After the detected cleanings, output stays flat (-0.003 %/day) instead of falling 0.215 %/day.
Questions and answers
| Question | Short answer | Verdict |
|---|---|---|
| Existing calculations | Equations mostly right; the 0.258 %/day rate and the observed interval come from noise-driven step detection. | Overstated |
| Are dust losses underestimated? | No. Rain tests cap plant-wide dust near 2.3 % after 21 to 42 dry days. | Not underestimated |
| Scenarios | A ₹0, B ₹0.91 L, C ₹5.54 L net a year. | B most credible |
| Interval and break-even | B: clean every ~31 dry days (4 rounds a year); pays only below ₹10.7 a module. | Whole-plant schedule |
| Biggest driver | Dust rate (swing ₹5.17 L), then cleaning cost and the rain threshold. | Rate must be measured |
| Physical validity | 12 logger-dump days, the portal's POA is really GHI, 27 cleanings are fault recoveries. | Fix data flags |
| Recommendation | Present B as the headline, A to C as the range, and a 60-day measurement plan. | Measured range |
Scenarios A, B and C. One year of real rain, best interval each.
| Scenario | Dust rate | Dust loss a year | Recovered | Interval | Cost a year | Net a year |
|---|---|---|---|---|---|---|
| A · Conservative | 0.050 %/day, saturating at 3 % Inferred | 27,936 kWh (0.66 %) | 0 kWh | No routine cleaning | ₹0 | ₹0 |
| B · Realistic | 0.100 %/day Inferred | 72,391 kWh (1.72 %) | 26,732 kWh | 31 d, 4× | ₹1,16,160 | ₹91,011 |
| C · Upper bound | 0.258 %/day Hypothetical | 1,88,655 kWh (4.48 %) | 1,16,417 kWh | 16 d, 12× | ₹3,48,480 | ₹5,53,751 |
| Input | Value | Basis |
|---|---|---|
| Energy a year | 4,210,888 kWh from the plant meter | Measured |
| Dust rate A and B | Rain jump ÷ dry days: 2.2 % ÷ 42 d and 2.3 % ÷ 21 d | Inferred |
| Dust rate C | The existing 0.258 %/day, 100 % removed by each cleaning | Hypothetical |
| Rain wash | 5 mm or more removes 90 % (3.4 mm did nothing, 6.5 mm did) | Inferred |
| Tariff and cleaning cost | ₹7.75/kWh and ₹6 a module (₹29,040 a round) | Assumed |
Break-even at ₹10.7 a module
B pays only while a cleaning costs less than ₹10.7 a module; the audit assumes ₹6 (₹29,040 a round). Under 15 days, A and B lose money.
Break-even, scenario B₹10.7a moduleNet ₹0.91 L at ₹6
Break-even, scenario A₹3.2a moduleBelow the assumed cost
Break-even, scenario C₹29.4a moduleCleaning every 16 days
Inputs that move the panel savings. The dust rate outweighs the rest.
Net savings of B at each input's low and high value. The thin line is the base case, ₹0.91 L; light bars fall below it, dark bars rise above it.
Dust rate (0.05 / 0.258 %/day)Low ₹0High ₹5.17 L
Cleaning cost (₹12 / 3 per module)Low ₹0High ₹1.70 L
Rain needed to wash (3 mm / 10 mm)Low ₹0.32 LHigh ₹1.71 L
Electricity value (₹5 / 10 per kWh)Low ₹0.17 LHigh ₹1.53 L
Dust saturates at 3 % (yes / no)Low ₹0High ₹0.91 L
Interval fixed at 15 / 62 days (optimum 31)Low −₹0.58 LHigh ₹0
Share of dust a cleaning removes (80 % / 100 %)Low ₹0.58 LHigh ₹1.02 L
Plant availability (95 % / 100 %)Low ₹0.81 LHigh ₹0.91 L
Median of 1,500 runs₹0.69 La year5th to 95th percentile: ₹0 to ₹3.70 L
Runs where cleaning does not pay27%Every input drawn across its range
Plant data problems
| Finding | Detail | Basis |
|---|---|---|
| Detected cleanings are not a cleaning log | 169 events at a 3.5 % threshold, about 1.5× the 2.3 % daily noise; noise alone gives 35. | Inferred |
| 27 cleanings are fault recoveries | They come within 30 days of one of 52 output drops and are counted as dust. | Calculated |
| Step size does not grow with days | r = 0.035 (p = 0.71) between step and days since the last reset. | Calculated |
| The POA sensor reads horizontal sunlight | Its readings track GHI; portal PR reaches 100 to 118 % on 3 to 10 Nov 2026. | Measured |
| 12 inverter-days are logger dumps | Above 7.2 kWh/kWp (max 9.99); flag and drop them. | Measured |
Measurements to confirm scenario C
Sixty dry days of these turn the range into one measured number.
| Data | Why | How |
|---|---|---|
| Crew cleaning log | True interval and cost, replaces detected events | O&M team: date, block, modules, water, ₹ |
| Clean and dirty reference modules | Direct dust rate, including saturation | 2 to 3 roofs, one module cleaned daily, 60+ dry days |
| Pyranometer cleaning log and a tilted reference cell | Removes sensor-dirt masking | Clean the sensor daily during the test |
| String or MPPT current around a cleaning | Measured step per block | 5-minute data, 3 days each side |
| Tilt, azimuth and string layout per block | Correct transposition and shading | Site survey |
| Inverter alarm log | Separates faults from dust | Ask the vendor; the portal has none |
| Real cost a module and avoided tariff | Economics | Crew invoices, PSPCL bill |